Parker D101VA belongs to D101 high-flow two‑stage directional valve family, air pilot operated version (D101VA = air pilot; D101VW solenoid pilot; D101VL lever; D10P hydraulic pilot)
Mounting: ISO4401, NFPA D10, CETOP10 / NG32 subplate manifold
Structure: 5‑chamber cast body, four‑land hardened main spool, air pilot drive
Pressure rating
P,A,B ports: 207 bar
Pilot air supply: Min 4.4 bar, max 207 bar
Drain: Internal drain limited to 34 bar; external drain up to 207 bar
Max flow: Up to 950 L/min (depends on spool code)
Spool options: 2‑position / 3‑position spool codes (001,003,004,008,011 etc.), closed centre, open centre, float centre, crossover
Return & latch: Spring return standard; detent latching option for holding position
Standard feature: Built‑in damping orifice for low‑impact shifting; fast‑shift version available by removing orifice
Seal: NBR standard; FKM/Viton optional for high temperature / special fluid
Optional: Spool position monitoring switch, ATEX/IECEx explosion-proof variant
Pilot medium: Filtered compressed air for pilot signal; main medium: hydraulic oil
Temperature: -20°C ~ +80°C (depends on seal)
Application: Remote pneumatic control for large hydraulic presses, metal forming, test benches, high-flow hydraulic stations, zones without electric power.
Brief comparison
D101VA: Air pilot operated, pneumatic signal control
D101VW: Solenoid pilot operated, electric control
D101VL: Manual lever operated
D91FC: Proportional valve, closed-loop electronic control