TEL: +86-021-60456283

Parker D101VA air operated directional valve, D101VA NG32 CETOP10 air pilot hydraulic valve, Parker D101 series directional valve, air pilot two stage directional control valve, high flow air pilot hydraulic spool valve

Download the universal directory in PDF format
Product Details

Parker D101VA belongs to D101 high-flow two‑stage directional valve family, air pilot operated version (D101VA = air pilot; D101VW solenoid pilot; D101VL lever; D10P hydraulic pilot)

  • Mounting: ISO4401, NFPA D10, CETOP10 / NG32 subplate manifold

  • Structure: 5‑chamber cast body, four‑land hardened main spool, air pilot drive

  • Pressure rating

    • P,A,B ports: 207 bar

    • Pilot air supply: Min 4.4 bar, max 207 bar

    • Drain: Internal drain limited to 34 bar; external drain up to 207 bar

  • Max flow: Up to 950 L/min (depends on spool code)

  • Spool options: 2‑position / 3‑position spool codes (001,003,004,008,011 etc.), closed centre, open centre, float centre, crossover

  • Return & latch: Spring return standard; detent latching option for holding position

  • Standard feature: Built‑in damping orifice for low‑impact shifting; fast‑shift version available by removing orifice

  • Seal: NBR standard; FKM/Viton optional for high temperature / special fluid

  • Optional: Spool position monitoring switch, ATEX/IECEx explosion-proof variant

  • Pilot medium: Filtered compressed air for pilot signal; main medium: hydraulic oil

  • Temperature: -20°C ~ +80°C (depends on seal)

  • Application: Remote pneumatic control for large hydraulic presses, metal forming, test benches, high-flow hydraulic stations, zones without electric power.

Brief comparison

D101VA: Air pilot operated, pneumatic signal control 

D101VW: Solenoid pilot operated, electric control 

D101VL: Manual lever operated 

D91FC: Proportional valve, closed-loop electronic control