Parker D*1FC series are two-stage pilot-operated proportional directional valves with built-in closed-loop spool position feedback and on-board digital amplifier.
· Frame sizes & ISO standard:
· D31FC: NG10 / CETOP 5
· D41FC: NG16 / CETOP 7
· D91FC: NG25 / CETOP 8
· D111FC: NG32 / CETOP 10
· Mounting: ISO4401 / DIN24340 subplate manifold installation
· Max pressure: P, A, B, X port up to 350 bar; T/Y drain port limited to 35 bar (external drain)
· Pilot supply: 20–350 bar, recommended 50 bar for optimal dynamic response
· Signal options: 0–10V / 4–20mA analog command; RS232 service port for parameter tuning
· Spool options: overlapped, zero-lap, progressive flow profile, centre position monitoring optional
· Performance: low hysteresis, high repeatability, good dynamic response; factory calibrated
· Seal: NBR standard, FPM/Viton optional for high-temperature or special fluids
· Ambient temperature: -20°C ~ +60°C
· Accessories: parameter cable, blanking plate, regeneration plate, service spool monitor
· Application: hydraulic presses, metal forming, fatigue test rigs, injection molding, material simulation, large machinery closed-loop motion control
Brief comparison
D31FC: NG10, small-medium flow, compact
D41FC: NG16, medium-high flow
D91FC: NG25, large flow
D111FC: NG32, maximum flow of this series
D*1FP: Voice coil servo-proportional variant, higher dynamic servo performance, different pilot drive principle
ch