TEL: +86-021-60456283

Parker Series D1MW Directional Control Valve

Download the universal directory in PDF format
Product Details

General introduction:

The D1MW is based on the D1VW series of directional control valves size NG06, but offers additional corrosion protection of the valve body, the solenoid coil and the anchor tube as well as the typical solenoid connections for the mobile market such as AMP Junior Timer and DT04-2P “Deutsch”.

D1MW = NG06 (CETOP‑03 / NFPA D03) direct‑operated solenoid directional spool valve, mobile‑duty enhanced corrosion‑resistant version of D1VW series. Main applications: steel‑structure fabrication machinery (H‑beam assembly machine, straightener, cutting equipment, material handling, mobile hydraulic system).

Technical features:

• High corrosion protection (optional)

• Solenoid connection:

- Standard (as per EN175301-803)

- AMP Junior Timer

- DT04-2P “Deutsch”

• Robust design for rough applications

• Extended manual override with rubber cover (optional)

Key Technical Specifications

Item

Parameter

Size

NG06 / CETOP-03 / ISO 4401-03, sub-plate mounting 

Max flow

80 L/min 

Max working pressure

P/A/B ports: 350 bar; T-port: 210 bar

Operation

Direct-acting wet solenoid, spring centering, optional manual override

Spool types

2-position / 3-position (001,004,008,009 etc.)

Fluid

Hydraulic oil DIN 51524, water-glycol; Seal: NBR (std), FPM (option)

Temp range

-25 ℃ ~ +60 ℃

Weight

1-solenoid:1.5 kg; 2-solenoid:2.1 kg

Body material

Cast iron, enhanced anti-corrosion coating for mobile environment

Max switching frequency

15 000 cycles / hour; 100% ED duty cycle

Solenoid & Connector Options

Voltage codes: K=12 VDC, J=24 VDC (common for industrial steel workshop)

Connector codes:

  • W: Standard DIN EN175301803, IP65

  • A: AMP Junior-Timer, IP67

  • J: Deutsch DT04-2P, IP69K (heavydust / outdoor mobile preferred)

Power 24VDC: Hold power ≈31 W, hold current 1.29 A

Difference vs D1VW: D1MW adds heavy-duty anti-corrosion coating on valve body, solenoid tube & coils; supports Deutsch / AMP mobile-style connectors; for harsh workshop / mobile machinery.

Typical Ordering Example

D1MW004CNJWW

  • D1MW = series

  • 004 = spool function 4 (3-position 4-way, P-blocked, A-B to T in mid-position)

  • C = sub-plate mounting

  • N = NBR seals

  • J = 24 VDC coil