Parker D101VW belongs to D101 series two-stage pilot operated directional spool valves, solenoid pilot actuation (D101VW = solenoid version; D101VA air pilot, D101VL lever, D10P hydraulic pilot).
Mounting: ISO4401, NFPA D10, CETOP10 / NG32 subplate manifold
Structure: 5-chamber main body, hardened four-land main spool, replaceable pilot solenoid
Pressure rating:
P/A/B ports: 207 bar (3000 psi)
Pilot supply: Min 4.4 bar, max 207 bar
Tank port: Internal drain limited to 102 bar (AC); DC / external drain up to 207 bar
Max flow: Up to 950 L/min (250 GPM, depends on spool selection)
Spool options: Multiple 2-position / 3-position spool codes (001,003,004,005,006,008,011 etc.), closed centre, open centre, crossover, float centre
Core feature: Standard built-in damping orifice for low-shock switching; fast-response option (remove orifice) for faster shift, not recommended above 138 bar
Electrical: AC / DC solenoid coil, conduit box style, no-tool coil removal, 100% continuous duty
Optional: I3 / I6 inductive spool position monitor for safety interlock; ATEX / IECEx explosion-proof variant; detented spool latching
Seal: NBR standard, FKM/Viton optional
Filtration requirement: ISO 4406 18/16/13
Fluid: Mineral hydraulic oil, compatible with selected fire-resistant fluids
Application: Large hydraulic presses, heavy metal forming, big test benches, high-flow hydraulic stations, large cylinder and hydraulic motor directional control
Brief comparison
D101VW: NG32 (CETOP10), pilot operated, ultra-high flow, solenoid pilot
D91FC: NG25 proportional valve, electronic closed-loop spool feedback, proportional regulation
D3W: NG10 direct solenoid operated, medium flow D1VW: NG06 direct operated, small-medium flow