TEL: +86-021-60456283

Yuken DM DMT Series Lever Manually Operated Directional Valve, Manual Change-over Valve

Download the universal directory in PDF format
Product Details

YUKEN DM / DMT Series Manually Operated Directional Valve

INTRODUCTION

DM / DMT series are Yuken lever-operated manual directional valves. They switch hydraulic flow direction by hand lever.

· DM: Threaded connection type

· DMT: Sub-plate mounting type Available with spring return (2B) or detent locking (2D / 3C). The lever angle can be adjusted to 5 different installation angles on site. Same installation interface as DMG series. Suitable for on-site manual control, emergency operation and test bench circuits without electric control.

SPECIFICATION

· Max working pressure: 31.5 MPa

· Max T-port back pressure: 21 MPa

· Working fluid: Anti-wear hydraulic oil ISO VG32 / VG46

· Viscosity: 15 ~ 100 mm²/s

· Fluid temperature: -20 ~ +80 ℃

Model

Max Flow (L/min)

Mounting

DMT-03

100

Sub-plate

DMT-06

300

Sub-plate

DMT-10

500

Sub-plate

DM-03 / DM-06 / DM-10

Same flow as DMT

Thread connection

MODEL CODE EXAMPLE:DMT-03-3C-50

Code

Description

F-

Fluorine seal for phosphate ester fluid (optional)

DMT

Sub-plate manual valve; DM = threaded pipe connection

03 / 06 / 10

Size

3C

3-position detent locking; 2B = 2-position spring return; 2D = 2-position detent

50 / 30

Revision number

Common spool functions:

· 3C: 3-position detent (stay in position after switching)

· 2B: 2-position spring return (release lever, spool auto reset)

· 2D: 2-position detent lock

APPLICATION

· Hydraulic test bench, inspection equipment

· Emergency manual override for heavy machinery

· Mobile hydraulic equipment

· Machine tool maintenance station

· Fixture manual clamping circuit

· Low-volume equipment without electrical control