电话: +86-021-60456283

Danfoss DST G290 gas sensor, DST G600 A3 refrigerant detector, photoacoustic R290 leak sensor, isobutane R600a sensor, ATEX refrigerant sensor, heat pump gas monitoring

下载PDF格式的通用目录
产品详情

Danfoss A3 Gas Sensor Series (DST G-series: DST G290 for R290, DST G600 for R600a), photoacoustic principle dedicated for A3 flammable hydrocarbon refrigerants. Measuring range 0–100% LFL; alarm threshold 15% LFL (G290, propane R290), 13% LFL (G600, isobutane R600a). Round low-profile inverted plastic housing, dew-point monitoring built-in for false-alarm suppression. Output options: relay contact, Modbus RTU, relay + Modbus combo. Supply 5VDC / 12–24V AC/DC, -40~80℃, 0–100% RH condensation resistant, CE / ATEX / IEC 60335-2-40 certified, no field calibration over full service life ≥15 years, poisoning immune. Response <30s, visible status LED, plug connector. For heat pumps, light commercial AC, domestic refrigeration, injection chillers using propane / isobutane refrigerants, original Danfoss

  • Family: DST G290 (R290) / DST G600 (R600a) A3 photoacoustic gas sensors

  • Core principle: photoacoustic spectroscopy, poison-free long life

  • Key selling point: lifetime no field calibration

  • Compare: DGS series = CO2 / A2L refrigerant sensors; DST G A3 = hydrocarbon flammable A3 refrigerants


Partial Models and Main Descriptions

073G2060

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] AC: 24, Supply voltage [V] DC: 24, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Modbus, Specification key: DST G290-A1-15 MODBUS ROUND I

073G2061

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] DC: 5, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Modbus, Specification key: DST G290-A0-15 MODBUS ROUND-I

073G2062

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] AC: 24, Supply voltage [V] DC: 24, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Dual, Specification key: DST G290-AB-15 DUAL ROUND-I

073G2063

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] AC: 24, Supply voltage [V] DC: 24, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Relay, Specification key: DST G290-B4-15 RELAY ROUND-I

073G5060

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] AC: 24, Supply voltage [V] DC: 24, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Modbus, Specification key: DST G290-A1-15 MODBUS ROUND-M

073G5062

Gas sensor, DST G290, R290

Alarm threshold [LFL %]: 15, Supply voltage [V] AC: 24, Supply voltage [V] DC: 24, Operating temperature [°C]: -40 - 80, Electrical connection: Mini Mate-N-Lok, Electrical connection size: 6 pin, Output signal: Dual, Specification key: DST G290-AB-15 DUAL ROUND-M