TEL: +86-021-60456283

Danfoss BCP7 pressure switch, dual bellows boiler pressure limiter, SIL2 TÜV category IV pressure switch, BCP3 overpressure safety controller

Download the universal directory in PDF format
Product Details

Danfoss Pressure Switches BCP Series (BCP1 / BCP2 / BCP3 / BCP4 / BCP5 / BCP6 / BCP7, fail‑safe dual bellows mechanical SPDT switch), dedicated for steam and hot water boiler pressure safety supervision. BCP1 low-pressure 0.03–1.1 bar; BCP2 0–2.5 bar; BCP3 0–6 bar; BCP4 1–10 bar; BCP5 2–16 bar; BCP6 5–25 bar; BCP7 high range 10–40 bar. Adjustable differential hysteresis, two reset options: automatic reset for regulation, tool-only manual reset for safety limit cut-off. Process connection G1/2 thread. Gold/silver plated SPDT contact, DIN 43650 plug connector, IP65, SIL2 certified, max medium temp 120°C, ambient -20~70℃. TÜV Category IV safety approved. For steam boiler, hot water boiler overpressure protection and alarm interlock, original Danfoss

  • Family: BCP1 / BCP2 / BCP3 / BCP4 / BCP5 / BCP6 / BCP7 boiler pressure limit switches

  • Core tech: fail-safe dual bellows

  • Manual reset version = safety limiter (tool reset only)

  • Compare: KP/KPI for refrigeration; BCP exclusive for boiler steam/hot water

.

Partial Models:

017B0002

Pressure switch, BCP1

Regulation range [bar] Pe: 0.1 - 1.1, Differential [bar]: 0.15 - 0.6, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 6

017B0006

Pressure switch, BCP2

Regulation range [bar] Pe: 0 - 2.5, Differential [bar]: 0.4 - 1, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 10

017B0010

Pressure switch, BCP3

Regulation range [bar] Pe: 0 - 6, Differential [bar]: 0.7 - 1.4, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 16

017B0014

Pressure switch, BCP4

Regulation range [bar] Pe: 1 - 10, Differential [bar]: 1 - 2.5, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 25

017B0018

Pressure switch, BCP5

Regulation range [bar] Pe: 2 - 16, Differential [bar]: 2 - 3.2, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 32

017B0020

Pressure switch, BCP5

Regulation range [bar] Pe: 2 - 16, Differential [bar]: 1.2, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 32

017B0022

Pressure switch, BCP6

Regulation range [bar] Pe: 5 - 25, Differential [bar]: 2.5 - 4, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 40

017B0026

Pressure switch, BCP7

Regulation range [bar] Pe: 10 - 40, Differential [bar]: 3 - 6, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 63

017B0030

Pressure switch, BCP1H

Regulation range [bar] Pe: 0.1 - 1.1, Differential [bar]: 0.1, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 6

017B0034

Pressure switch, BCP2H

Regulation range [bar] Pe: 0 - 2.5, Differential [bar]: 0.2, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 10

017B0038

Pressure switch, BCP3H

Regulation range [bar] Pe: 0 - 6, Differential [bar]: 0.4, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 16

017B0042

Pressure switch, BCP4H

Regulation range [bar] Pe: 1 - 10, Differential [bar]: 0.45, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 25

017B0046

Pressure switch, BCP5H

Regulation range [bar] Pe: 2 - 16, Differential [bar]: 1.2, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 32

017B0050

Pressure switch, BCP6H

Regulation range [bar] Pe: 5 - 25, Differential [bar]: 1.5, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 40

017B0054

Pressure switch, BCP7H

Regulation range [bar] Pe: 10 - 40, Differential [bar]: 2.3, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 63

017B0058

Pressure switch, BCP2L

Regulation range [bar] Pe: 0 - 2.5, Differential [bar]: 0.2, Reset function: Manual Min, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 10

017B0062

Pressure switch, BCP3L

Regulation range [bar] Pe: 0 - 6, Differential [bar]: 0.4, Reset function: Manual Min, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 16

017B0066

Pressure switch, BCP4L

Regulation range [bar] Pe: 1 - 10, Differential [bar]: 0.45, Reset function: Manual Min, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 25

017B0070

Pressure switch, BCP5L

Regulation range [bar] Pe: 2 - 16, Differential [bar]: 1.2, Reset function: Manual Min, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 32

017B0074

Pressure switch, BCP6L

Regulation range [bar] Pe: 5 - 25, Differential [bar]: 1.2, Reset function: Manual Min, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 40

017B0110

Pressure switch, BCP3

Regulation range [bar] Pe: 0 - 6, Differential [bar]: 0.7 - 1.4, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 16

017B0114

Pressure switch, BCP4

Regulation range [bar] Pe: 1 - 10, Differential [bar]: 1 - 2.5, Reset function: Auto, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 25

017B0138

Pressure switch, BCP3H

Regulation range [bar] Pe: 0 - 6, Differential [bar]: 0.4, Reset function: Manual Max, Pressure connection type: G, Pressure connection size: 1/2, Enclosure rating IP: IP65, Max. Working Pressure [bar]: 16

Notes:Not all informations are shown.Contact Danfoss engineers for assistance