HYDAC HTT 1200S smart temperature transmitter, belongs to HTT1200 family.
Measuring element: PT1000
Measuring range: -25 ~ +125 °C, optional extended version -40 ~ +125 °C
Accuracy: typical ±1.0% FS, max ±2.0% FS
Interface: IO-Link V1.1 (Smart version); other HTT1200 variants: 4–20mA analog, CANopen, SAE J1939
Probe length options: 16 mm / 40 mm / 50 mm, custom lengths available
Process connection: G1/4 external thread
Pressure rating: max 600 bar
Supply voltage: DC 9–30 V
Housing: stainless steel, compact integrated construction
Protection: IP67, reverse polarity protection, high shock & vibration resistance
Operating ambient temp: -25 ~ +85 °C
Application fields :
Wide range of applications within the mechanical engineering sector, such as:
- Hydraulics
- Pneumatics
- Cooling systems
- Compressors and much more
NOTES
Core difference: HTT1200S = IO-Link smart version; standard HTT1200 = analog / CAN / J1939 signal only
Core difference vs ETS series: ETS is temperature switch; HTT1200S is continuous temperature transmitter
Main application: hydraulic oil temperature measurement
Models:
HTT1246S-F31(-1)-016-000
HTT1246S-F31(-B)-016-000
HTT1246S-F31(-C)-016-000
HTT1246S-F31(-1)-040-000
HTT1246S-F31(-B)-040-000
HTT1246S-F31(-C)-040-000
ch
English