TEL: +86-18821243325

Eaton Vickers Pressure Reducing Valves for Line Mounting-XT-03, 20 Series X(C)T-06/10, 20 Series

Download the universal directory in PDF format
Product Details

Basic Characteristics

Maximum supply pressure 210 bar . . . . (3000 psi)

Maximum flow 284 l/min . . . . . . . . . . . . .(75 USgpm)

General Description

Pressure reducing valves are used to reduce system pressure to a constant reduced outlet pressure regardless of fluctuations in the main system above the selected pressure.

The XCT models have an integral check valve that allows free flow from the outlet

connection to inlet connection.

Maximum Pressure

Inlet ports 210 bar (3000 psi) . . . . . . . . .

Drain ports 1,7 bar (25 psi) . . . . . . . . . . .

Note: Drain ports must be piped direct to

reservoir. Any back pressure at this port will

increase the effective pressure setting of the

valve by the same amount.

Max. Flow Rate and Min. Reduced Pressures

Typical with petroleum oil at 21 cSt (102 SUS) and at 50 C (122 F).

Temperature Limits

Ambient:

Minimum . . . . . . . . . . . . . 200C (4 0F)

Maximum +70 . . . . . . . . . . 0C ( +1580F)