Eaton Vickers XT‑03, XT‑06, XT‑10 (20 Series) line-mounted pilot-operated pressure reducing valves; XCT variant integrates a check valve for reverse free flow.
XT: Basic pressure reducing valve, no reverse check
XCT: Reducing valve + built-in check valve, free reverse flow when outlet pressure exceeds inlet
Port thread:
XT‑03: G3/8
XT‑06: G3/4
XT‑10: G1¼
Max inlet pressure: 210 bar
Spring pressure ranges:
B: 5–70 bar
C: 35–140 bar
F: 100–200 bar
Rated flow:
XT‑03: Max 53 L/min
XT‑06: Max 114 L/min
XT‑10: Max 284 L/min
Adjustment: Handwheel / screw locknut, clockwise to raise pressure; valve cover rotatable for convenient adjustment orientation
Auxiliary ports: Remote control port, gauge test ports, external drain port
Body: Cast iron, hardened pilot spool; NBR seal standard, Viton optional
Function: Maintain stable outlet pressure for sub-circuits regardless of fluctuating inlet pressure; remote control available
Application: Machine tool clamping, lubrication circuits, auxiliary low-pressure branches, hydraulic power stations
Brief comparison
XT: Standard reducing valve, no reverse check
XCT: Reducing valve + built-in reverse free-flow check
XT‑03: Small size, 53 L/min
XT‑06: Medium size, 114 L/min
XT‑10: Large size, 284 L/min
DGMPC / DGMX2: SystemStak sandwich reducing valve, subplate stacked installation, not line threaded
ch