Eaton Vickers XT-03 pressure reducing valve, XCT-06 XCT-10 reducing valve, line mounted pilot operated reducing valve, threaded hydraulic pressure reducing valve, Vickers XT 20 series reducing valve, reducing valve with reverse check valve

Download the universal directory in PDF format
Product Details

Eaton Vickers XT‑03, XT‑06, XT‑10 (20 Series) line-mounted pilot-operated pressure reducing valves; XCT variant integrates a check valve for reverse free flow.

  • XT: Basic pressure reducing valve, no reverse check

  • XCT: Reducing valve + built-in check valve, free reverse flow when outlet pressure exceeds inlet

  • Port thread:

    • XT‑03: G3/8

    • XT‑06: G3/4

    • XT‑10: G1¼

  • Max inlet pressure: 210 bar

  • Spring pressure ranges:

    • B: 5–70 bar

    • C: 35–140 bar

    • F: 100–200 bar

  • Rated flow:

    • XT‑03: Max 53 L/min

    • XT‑06: Max 114 L/min

    • XT‑10: Max 284 L/min

  • Adjustment: Handwheel / screw locknut, clockwise to raise pressure; valve cover rotatable for convenient adjustment orientation

  • Auxiliary ports: Remote control port, gauge test ports, external drain port

  • Body: Cast iron, hardened pilot spool; NBR seal standard, Viton optional

  • Function: Maintain stable outlet pressure for sub-circuits regardless of fluctuating inlet pressure; remote control available

  • Application: Machine tool clamping, lubrication circuits, auxiliary low-pressure branches, hydraulic power stations

Brief comparison

XT: Standard reducing valve, no reverse check 

XCT: Reducing valve + built-in reverse free-flow check 

XT‑03: Small size, 53 L/min 

XT‑06: Medium size, 114 L/min 

XT‑10: Large size, 284 L/min 

DGMPC / DGMX2: SystemStak sandwich reducing valve, subplate stacked installation, not line threaded